LinkedIn




Rack 0.6 to 1.0 kVA

PersonalSource™ Rugged COTS
Configurable Rackmount UPS
600 VA, 800 VA and 1000 VA


True On-Line Design

RS232 Communications
Input Power Factor Correction Site Wiring Fault indicator
Built-in Surge Protection Green Mode Operation
Microprocessor Control &  Communications Compatible with generators
Compact size, lightweight Optional internal SNMP/HTTP
Wide input voltage window Optional Extended Battery Time
High Efficiency Optional Frequency Conversion
Over crest ratio indicator  


PersonalSource Rugged COTS Rackmount600 to 3000 VA Front View


PersonalSource Rugged COTS Rackmount600 to 3000 VA Rear View

True On-line Design

A recent Bell Laboratories study indicates that blackouts accountfor less than 5% of power disturbances. The other 95% consist of surges, noise,sags and brownouts. Equipment connected to utility power experiences an averageof 128 such events each month. These events can disrupt proper operation ofsensitive computer based equipment, decreasing productivity and createsunnecessary production, service and data recovery costs.

A True On-line UPS is the only design that can provide the maximumprotection against major power problems. This is accomplished through convertingthe incoming AC utility voltage to a DC voltage. From this DC voltage, an ACvoltage is then completely regenerated by the UPS, providing a clean,well-regulated source to your equipment, thereby eliminating power relatedproblems. This solidstate generator sets the True Regenerative On-Line UPS apartfrom all other Line-interactive and Off-line designs, which leave your sensitiveequipment connected directly to the dirty utility power 99+% of the time. Ifyour equipment is operating in a “Mission Critical” application, then youneed a True On-line UPS and the PersonalSource is the best choice in TrueOn-line UPS technology.

Input Power Factor Correction

All PersonalSource Seriesmodels include state of the art Input PowerFactor Correction. This greatly reduces the amount of current demanded fromyour building wiring system, yielding an efficient,  “building friendly” UPS.

Microprocessor Control

The PersonalSourceUPS incorporates advanced microprocessor technology. This technology makespossible a high level of internal UPS control as well as system information,data logging, self-diagnostics, SNMP and enhanced computer communication throughany RS-232 port.

SNMP/HTTP RemoteManagement Support

An optional SNMP/HTTPAgent board is available for direct installation into all PersonalSource models.The SNMP/HTTP Agent provides for direct connection of the UPS to any 10BaseT Ethernet LAN.  

Overall, the PersonalSource Series is uniquely qualified for critical systems combining advanced modular design features with highlyreliable construction.

PART NUMBER:

 ETI0015
-2201

 ETI0015
-2211

 ETI0015
-2202

 ETI0015
-2212

 ETI0015
-2203

 ETI0015
-2213

INPUT

Nominal Voltage

120  VAC

230  VAC

120  VAC

230  VAC

120  VAC

230  VAC

Voltage Range

87-140 V

170-255 V

87-140 V

170-255 V

87-140 V

170-255 V

Current (max)

4.5 A

2.5 A

6 A

3.3 A

7.3 A

4 A

Frequency

50/60 Hz ±5%

Efficiency

>89%

>86%

Power Factor

>0.95

OUTPUT

VA Rating

600 VA

800 VA

1000 VA

Power

420 W

560 W

700 W

Voltage (selectable)

110  VAC

220  VAC

110  VAC

220  VAC

110  VAC

220  VAC

115  VAC

230  VAC

115  VAC

230  VAC

115  VAC

230  VAC

120  VAC

240  VAC

120  VAC

240  VAC

120  VAC

240  VAC

Frequency:

50 or 60 Hz (auto tracking)

Voltage Regulation:

±2%

Frequency Stability:

±0.3% (Battery mode)

Step Load Change:

±7% for 100% load variation

Harmonic Distortion:

Linear Load <3%
Non-linear Load <5% 

Overload:

105% load for 50 seconds

Crest Ratio:

3:1

BATTERY2

DC Voltage:

36 VDC

Type:

Maintenance Free, Valve Regulated, Sealed Lead Acid, Flame Retardant, Absorbed Electrolyte

Backup time

Full Load
Half Load

13 minutes typical
36 minutes typical

9 minutes typical
25 minutes typical

6 minutes typical
19 minutes typical

Recharge Time:

8 Hours to 90%

TRANSFER TIME

Line Fails/Recovers:

Zero time – true online, no transfer for brownout or blackout

UPS to Bypass or Reverse:

<4 ms for bypass transfers

After Overload:

Auto Transfer to UPS

Audible Noise

@ 1 Meter

<50 dBA

Indicators

LEDs:

Line, Inverter, Battery Reserve, Load, Bypass, Alarm, Crest, Battery & Load Capacity Level

Audible Alarms

 

DC Mode, Low Battery, Over/Under Voltage, Over/Under Frequency, High Temperature, Over Load, Alarm.

Interface

Computer:

UPS industry style RS-232

Environment

Temperature:

0°C - 40°C (32°F – 104°F)

Humidity:

10% - 95% Non-condensing

Mechanical

Input Line Cord:
    120 VAC
    230 VAC

6 Foot Cord with NEMA 5-15P Plug

6 Foot Cord with “Schuko” Style Plug

Output Receptacles:
    120 VAC version
    230 VAC version

(6) NEMA 5-15R w/ cable bales

(6) IEC320 w/ cable bales

Weight:

xx lbs (xx kg)

xx lbs (xx kg)

xx lbs (xx kg)

Dimensions:
Inches H x D x W (mm)

5.25 (3U) x 26.0 x 19.0
(133 x 660 x 483)

Approvals

Agency:

UL, CUL,  FCC Class A (CE on European models only)

 

ETI Rugged Power UPS are the proven Standard!

Contact Us for a Free Quote
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466