P/N: ETI0001-2221 2.2 kVA Rugged Rackmount MilSpec UPS and Frequency Converter, NSN: 6130-01-537-3889

Part Number:
ETI0001-2221
NSN: 6130-01-537-3889
Rugged Mil Spec® Rack or Fixed Mount
2200 VA UPS
Both AC and DC Outputs
Hot Swappable Batteries


US Navy AN/WDL-1 Mine Sweeper Standard Product
2.2 kVA Mil Spec UPS w/ AC and DC Outputs
Rugged Rack or Fixed Mount Unit 
w/ Reduced Depth and Removable Battery Modules

<br />ETI0001-2221 Rugged MilSpec UPS Standard Front Panel Layout



ETI0001-2221 Rugged Mil Spec UPS Standard Front Panel Layout

NSN: 6130-01-537-3889

<br />ETI0001-2221 Rugged MilSpec UPS Standard Rear Panel Layout

ETI0001-2221 Rugged Mil Spec UPS Standard Rear Panel Layout

The field proven Military Power® UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, ruggedconstruction, compact size and light weight design. These units are equallysuited for use in shipboard, airborne, vehicular, field deployed or fixedlocations with controlled or uncontrolled environments. The"
ETI0001-2221" is being used by the US Navy on the WLD-1 project becauseof their stringent performance and reliability requirements. 

The heavy-duty chassis,occupying only 10.5" (6U) of rack space and 19" depth, has rounded metal cornersand rugged handles front and rear, aiding in safe handling. Internally, all majorcomponents are well secured and electrically insulated to prevent damage due to shock andvibration. 

The internal shieldedinput transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) inputvoltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operatesas a frequency converter, taking 46-440 hertz input and converting it to clean,uninterruptible 60 hertz power. The input switch and the galvanic isolationtransformer all provide a double pole isolated source for all installations including shipboardsystems or overseas locations where phase references and grounding are notconsistent. 

The LED arrays keep theoperator informed as to the unit's status including load and battery levels. Thehigh intensity audible alarm can be heard in high noise environments. All controlsand protective devices are brought to the front and rear panels with critical switches having fingerguards. Further, all front panel devices are recessed to prevent damage or accidentaloperation. Variousoptional power distribution controls are available which mount on the front panel orremotely. 

The rear panel provides barrier terminalblocks for the input and outputpower. Multipleinput and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provideadded protection in both controlled and hostile environments. The exhaust air is diverted out therear vent, with alternateair flow directions optional. The "
ETI0001-2221" has the added benefit of havingfield replaceable batteries via a front drawout battery modules. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides aninterface with optional computer software providing loss of AC and low battery status as well asremote shut down capability. 

See the Power Distribution Units section for alisting of stand alone PDUs. See the N5 Series
ETI0001-1482
for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for criticalshipboard, vehicle, airborne or land based systems combining advanced modular designfeatures with highly reliable construction.

Technical Specifications:
P/N:
ETI0001-2221

NSN: 6130-01-537-3889

OUTPUTS
Output voltage: 
    UPS AC:
    UPS DC:


120 VAC true sinewave standard
28 VDC isolated
28 VDC isolated
28 VDC isolated
Output rating: 
    UPS Total:
    DC Outputs:

 

2200 VA total including DC outputs, up to 1500 VA AC
5 amps @ 28 VDC
11 amps @ 28 VDC
15 amps @ 28 VDC respectively
Non-linear load capacity: UPS Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: UPS 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: UPS Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 1.0% independent of input frequency
50, 400 or 1000 Hz output available as an option
Operational status Status, load and battery LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
AC INPUT
Input voltage selection: Nominal 115 VAC, optional autoranging input of 85-270 VAC
Input voltage tolerance: UPS 85-135 VAC @ full load without using battery, to 70 VAC @ 75% load
Input frequency: From 46 Hz to 440 Hz standard
Input power factor: Better than 99% typically
Input/output isolation: 2200 VA, up to 120 dB common mode, <1.0 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole toggle circuit breaker
Input power connection: Barrier terminal block
INTERNAL BATTERY
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal DC protection: Front panel mounted fuse standard, breaker optional
Internal battery time: 30+ minutes @ 100% load, 60+ minutes @ 50%
Internal battery recharge: Recharged to nominal in <8 hours
Internal battery replacement: (2) Drawout/plug-in modules from front of unit
DISTRIBUTION PANEL
Output circuits: Four outputs standard, optional configurations
Output control: Guarded toggle circuit breakers
Output receptacles: Barrier terminal blocks
MECHANICAL
Dimensions ( H x D x W ): 10.5 (6U) x 19.1 x 19.0 in (267 x 485 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight:
  UPS w/o Battery
  Internal Battery Module

95 lb. (43 kg) UPS with lift handles front and rear
64 lb. (29 kg) Each Battery Module
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Front intake, exhaust to rear, others optional
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C) with fully charged batteries
Operating temperature: -4° to 131° F ambient ( -20° to 55° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 
OPTIONAL ACCESSORIES
Autoranging International Input, Cold Start, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface,  Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits
Contact Us for a Free Quote